Nrsx k pro calibrations bookshelves

The second includes reflashes and fully programmable systems for k series engines. We are an authorized hondata dealer and kpro installer which means we can do the modifications to the ecu and install the kpro board into your ecu at our facility. Calibration facility locations national calibration inc. Twice the on board datalogging memory three times the prog. Hondata fully tunable ecus for allmotor and forced. Procalibration, llc providing metrology and repair. The original table of contents and several legacy sections are provided here as reference only. Hondata kpro v4 for kseries engine management hybrid racing. Guided calibrations allow as many standards as needed.

To use the k pro on a 20052006 rsx, an adapter harness is required, an 0204 specially modified ecu must be modified for used and the primary oxygen sensor from an 0304 must be used. Regular internal calibration audits against iso 9001, as9100, iso 485. The 0506 k pro is only certified to work in an 0506 rsx. Fieldonsite calibration services save time with onsite support our onsite coordination services are fully customizable to meet your companys specific equipment needs. Unless otherwise specified, all calibrations are performed according to standard manufacturing procedures as provided with the sensor at the time of original purchase expedited and blanket calibration services are available need to calibrate a. Minimizing the number of physical connection of standards. It includes windows based software called flashpromanager.

Calibration classes are assigned in the advanced modify cal kit menu, solt or trl tab. It is specially adapted from an acura rsx ecu allowing the reprogramming and datalogging of sensors for the 0005 honda s2000. Browse top posts starting with the letter n page 14. In the case of air sampling calibration is the setting of the air flow through the filter medium to the recommended level for the method being used. Systemsure luminometers are designed to selfcalibrate at startup, but some companies require additional verification of calibration. Ias accredits calibration laboratories to isoiec standard 17025. Ive also checked all my vacuum hoses i am running an rbb intake manifold and they are fine.

Pro calibration, llc providing a wide range of calibration metrology and repair services for mechanical, electronic, temperature, pressure and hvac air flow equipment. However, you may choose to calibrate one time for multiple paper types if the papers are very similar. Nci is an a2la accredited calibration and repair service company providing service and sales for measuring and test equipment to clients across the united states. Cal all offers a single, optimized calibration procedure for all channels with some limitations, see below. Calibrate all channels programming examples separate topic other cal topics. Hondata modifies standard honda engine computers ecus, adding features and expanding the capabilities of the ecu e. The k pro ecu is a specially modified 2002 to 2004 honda ecu with an usb interface to a notebook pc running windows xp. Castles, like old test equipment, last when they are maintained. Location of national calibration, inc nci facilities. The rsx ecu is not compatible with the 0607 drive by wire, so the s2000 k pro cannot be used. In todays video we prepare the rsx for its inevitable kpro install and im going to show you how its done. Link to the calibration, or upload it as an attachment.

Ktuner allows the ability to properly tune ignition, fuel, cam angle, and additional supporting parameters required to meet emissions standards. Core computer required k pro iii consists of a hardware modification to certain k series ecus, plus windows software which allows you to reprogram the ecu and datalog sensors. Buy hondata kpro iii customer supplied ecu hdkpro at king motorsports unlimited, inc hondatas k pro allows you to get the absolute most power out of your d, f or k series, while maintaining excellent reliability. I need to dyno but the place i dyno at said that their dyno is down right now. In addition to all the standard features k pro iii has the following enhancements. A new generation of hybrid dry calibration tables are being made that separate water pumping and vacuum systems and offer variable lengths to install calibration tooling. The k series programmable ecu kpro consists of a hardware modification to any k series ecu, plus windows software which allows you to reprogram the ecu and datalog sensors. The hondata k series programmable ecu k pro consists of a hardware modification to any honda k series ecu, plus windows software which allows you to reprogram the ecu and datalog sensors. Minimizing the number of power meter calibration sweeps. The number of standards assigned to a given class may vary from one to seven for unguided calibrations. Onboard datalogging is standard on all k pros from serial number 4111 version 2and above. An ecu and o2 sensor from an 0204 rsx are required, the 0506 rsx ecu cannot be used. Lab equipment calibrations raeyco lab equipment systems.

As with the other k pro applications, you can supply your own ecu for modification, or you can choose to purchase a new prb ecu. Na k pro calibration thread this a thread where we can all share our calibrations. Tps calibration on a hondata kpro v4 acura rsx frank build duration. Calibration is one of the most important considerations for any quantitative analysis, and our range of standards and accessories will make calibrating your td system as easy as possible. Tuning may be necessary not only to get the best possible performance but also because the base k pro calibration may cause the engine to knock. Hondata kpro version 4 is a fully programmable ecu for 0506 acura rsx dc5. Nist s calibration services are temporarily nonoperational and we are not accepting new orders.

In this case, the fiery server stores different measurement data for each calibration. A brand new ecu kpro 0204 prb ecu for 0204 or 0506 rsx vehicle use. Otc recommends a starting periodicity of 12 months for most instruments with an increase in calibration frequency to 6 or 9 months if adjustment is required, and a reduction in periodicity to 2 years after a sequence of annual calibrations has shown that adjustment has not been needed. The first category includes fully tunable systems for bseries, dseries, hseries and fseries engines. To start viewing messages, select the forum that you want to visit from the selection below. Nist traceable standard calibrations united states. This s2000 kpro requires a user supplied rsx prb ecu adapted for the s2000, and a wiring harness for the crank and cam sensors. Those in charge of test equipment must here weigh up the risks against the costs to achieve an optimum balance between security and costs. I have a 2006 acura rsx types and am looking for a good calibration to use on my car that has a comptech race header, comptech catback exhaust, and injen cold air intake.

Free shipping, financing available, live inventory, authorized dealer since 2001. If this is your first visit, be sure to check out the faq by clicking the link above. Buy hondata 0005 s2000 kpro kpros2000 at k series parts. The term calibration refers to a complete set of cam angle, ignition, and fuel tables, as well as additional settings that can be made with the k pro. K pro 4 consists of a hardware modification to certain k series ecus, plus windows software which allows you to reprogram the ecu and datalog sensors. Requires the use of a 20022004 acura rsx engine harness and a 20022004 acura rsx 6 speed manual transmission. Nist is committed to the health and safety of our employees and the american public and is supporting social distancing efforts. In this video, i show you the steps if how to calibrate the sensor utilizing kpro and the hondata ecu editor. Hondata kpro s2000 with ecu 0005 s2000 hondata kpro s2000 is a programmable ecu that extends from the k series hondata kpro line. The kseries programmable ecu kpro consists of a hardware modification to any kseries ecu, plus windows software which allows you to reprogram the ecu and datalog sensors. The ecu is the approximate size and shape of the s2000 ecu, and is located with the same. S2000 k pro upgrade once the k pro was up and running on my daily driven street car, tuning was a snap. This video will help you calibrate scale your tps using k pro. Internally, the 1030 box has always been the rsx ecu which is going to be released in.

Calibrate your rae systems monitors effectively and efficiently and stay in compliance using our calibration tools and kits. Calibration, repair, mobile, onsite national calibration. Turn around time is usually 2 days from the time it is received. Click here for listing of calibration options available. Hondata k pro, hondata kpro dynamic performance racing. In addition to the autorae 2 and autorae lite calibration systems that deliver automatic bump testing, calibration, charging and data management, rae systems offers a full range of accessories for automatic or manual calibration. We send you recall notices before your equipment calibration expires, and if we dont hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Na kpro calibrations acura rsx, ilx and honda ep3 forum. Although longer calibration intervals mean lower costs, they also involve a huge risk of nonconformity of the measuring instrument. User supplied ecus must be checked before sending to hondata. Any damaged or faulty ecus will incur a processing cost. This allows micro precision calibration service to provide stateoftheart test equipment calibration services that calibrate almost any mechanical, electronic, or dimensional instrument. K pro calibrations k series programmable ecu calibration updates downloads 1090 topics 4982 posts last post k20a2 fully tuned na calibra by ak57 mon apr, 2020 8.

Hkct provides exceptional onsite and inhouse calibration services for all types of test and measurement instrumentation such as fluke digital multimeters and air flow meters. I have a 02 rsx type s i recently swap my k20a2 with a jdm k24a, i have kpro v4 i tried the map for rsx with k24a2 intake and headers i think but it kept bringing up my speed sensor check engine light, so i finally use under others tsx stock cal and it work fine for 2 months, so i recently put my previous cut rbc manifold with hondata img, i had to get the ktune coolant adapter and. Nci is an equipment calibration and repair company with facilities in the western united states. The service and calibration laboratory in bethlehem, pa has been specifically developed to meet the needs of our usa customer and, whilst fully traceable to national standards, is intended to be flexible in its approach to providing practical service solutions. Incorporating the calibration control kit into your overall quality control program will confirm that the. A calibration interval is the regular time period between calibrations. But it has been optimized for my car with only the cai and kpro. Our calibration certificates include a preventative maintenance checklist with results, electrical safety checks as per csa c22. Pretty much all of the knock is gone i might want to datalog a bit to double check cuz i think i saw the mil flash one time after driving up and down hills in 5th then cruzing for a while in 6th and then downshifting once to 5thif all that made sence. Here is a quick video done by hondata showing how to. The hondata kseries programmable ecu kpro consists of a hardware. Instead, they will start with one of the many library calibrations that come with the k pro s k manager software. Fieldonsite calibration services from scheduling to. Rkc calibration micro precision provides calibration for all types of rkc instruments, calibration test equipment sale and repair.

From simple boltons, to big builds and forced induction, your d, f or k series will produce more power when paired with hondatas k pro iii. But the car idles from 1 and 2 not constantly but randomly. Early tables that utilized this technology had the drawback of having a fixed length of rail section for the dry calibration to allow for the specialized auxiliary tank. Primarily to tuning the honda k series engines used in the acura rsx and honda civic hatch with a hondata k pro ecu and hondata k manager software. Hey guys, i am new here but i have a 2002 rsx s with an 04 k24a2. This accreditation demonstrates to the marketplace and to regulators that calibration laboratories have met the industry recognized requirements for measurement traceability and undergo a program of periodic monitoring by ias. Skc offers a range of calibration equipment, and the choice of which calibrator depends on. In this video we dive deep into tuning the rsx, but there is some bad news.

As a bonus your will find that your brand new valve cover is not dirty and has no oil stains. Base kpro calibrations acura rsx, ilx and honda ep3 forum. Engine swaps using an 0506 rsx engine and gearbox into another chassis are not supported with the 0506 k pro and adapter harness. Xenocron tuning does not sell hondata products outside the us if you are an international customer, please follow this link to. Reddit has hundreds of thousands of interestbased communities. And while driving the car feels the need to jerk if i drive it slow. During the calibration the white standard shows the instrument a defined color, in our case a white with a reflectance of about 98%. K series programmable ecu calibration updates downloads. Hondata kpro v4 for kseries engine management hybrid. Calibrations are performed at your facility, or at our sparks nevada laboratory. K pro calibrations k series programmable ecu calibration updates downloads 1090 topics 4982 posts last post k20a2. How to clean white calibration standards erx series. The kpro is obviously a great ecu, but ive put it on the shelf for the time being in.

Hb 145 was developed as a source of calibration procedures for weights and measures laboratories and covered mass, length and volume calibrations for field standards used in the commercial marketplace. A 2port calibration requires 10 classes, not including two for isolation. Tps calibration on a hondata kpro v4 acura rsx frank build. This is also how you would calibrate a bseries or mustang tps on a k series setup. The hondata kpro comes with a number of calibrations for various engine configurations. Our standard calibration procedure encompasses a threepoint asfound calibration verification. Lab equipment calibrations raeyco lab equipment is a specialist in calibration of all lab equipment. The hondata kpro v4 is a powerful tool for unlocking your engines real performance. Ive changed my map sensor, tps, and o2 sensor but the car afr goes from 16 to 20. Na kpro calibrations page 5 acura rsx, ilx and honda. Calibration industry service leader national calibration inc. If the fiery server supports multiple calibrations, you can perform the calibration procedure for each one, using the appropriate paper type in each case. The k series programmable ecu k pro consists of a hardware modification to any k series ecu, plus windows software which allows you to reprogram the ecu and datalog sensors.

The high resolution maps on the k pro allowed us to quickly resolve. If you have any questions, feel free to send me a message. Ncis extensive onsite program has the capacity to also service numerous national account customers. The absolute repeatability of a spectrophotometer depends also on the quality of the calibration. Hondata kpro 0506 rsx core required this is a hondata modified 20022004 rsx ecu and an adapter harness for the 0506 rsx hondata makes hardware modifications to the 20022004 ecu enable it to work with the different sensors and actuators found o. Na kpro calibration thread this a thread where we can all share our calibrations. I will also be trying park82s kal once i can get some dyno time. The flashpro connects from your laptops usb port to your vehicles diagnostic port to provide live tuning with a variety of calibrations, extensive real time and stored datalogging capabilities. Csi is an onsite and inhouse calibration firm specializing in calibration, and service of mechanical testing devices. By customizing each instrument calibration within procalv5, calvex can offer calibration programs that are tailored to fit your needs, such as singlepoint, loop calibrations, or verifications.

I have a feeling this calibration will most probably result in more power the just using the cold air kal but once again no actual data yet. For over 40 years, we have provided comprehensive calibration and service to clients in 11 states, the caribbean u. Paired with essential datalogging parameters at high speeds, ktuner can be utilized to test and develop multiple vehicle platforms in the development of emissions legal aftermarket performance products. Hondata kpro iii customer supplied ecu hdkpro king. Hondata kpro and flashpro systems you get low and high tables but. Choice of brand new ecu w k pro installation, customer supplied core ecu for k pro installation, or used ecu for k pro installation. Maf sensors do tend to have a fairly limited shelf life and rarely last the entire. The flashpro allows full user tuning and datalogging for your select vehicles. These torque wrench calibration systems will test and calibrate most types of torque wrenches, torque screwdrivers, torque multipliers, cable tensiometers, tension and compression gauges and non impact power tools such as nut runners and.

Hondata kpro version 4 0204 rsx, 0506 rsx, 20012006. Hk calibration technologies pty ltd hkct is a highly regarded specialist calibration services company with laboratories australiawide. Our lab is environmentally controlled and provides a wide range of calibration metrology and repair services for mechanical, electronic, temperature, pressure and hvac airflow equipment. Check out the deal on hondata kpro version 4 at k series parts. The link bellow will drop you to the same hondata k pro k series programmable ecu but for a different car. I could use some help, 06 k24a2 rsx type s tsx manifold rsx tb, and rsx header with exhaust. Those unfamiliar or unwilling to learn k pro operation and the principles behind it can still use the k pro to good advantage, but they should expect to pay a tuner to tune the car properly. Most people will not create a k pro calibration from scratch.